Eubacteria Diagnostic Service

 
 

Expert eubacteria testing in cell cultures & other biological materials

down Test Specifications

down Available Testing Procedures

down Report

down Sample Preparation

down Shipping Instructions

down Special Preparation for Cell Culture Samples

down Please Note



Test Specifications 

The validated Ona®EUB Eubacteria Detection Kit is employed: reliable and sensitive providing a yes/no result, with a detection range of more than 45 eubacteria species: e.g. Pseudomonas, Micrococcus, Actinomyces, Bacillus, Escherichia coli, Klebsiella, Serratia, Salmonella, Porphyromonas, Enterococcus, Fusobacterium, Mycobacterium, Staphylococcus, Streptococcus, Prevotella, Lactobacillus, Peptostreptococcus. All samples are tested in parallel with positive and negative controls, as well as with an internal amplification control. Processing and results provided via fax usually within the same day.



Available Testing Procedures 

Direct testing of DNA extracts. Definitive exclusion of possible contaminations in biopharmaceuticals, supplements, serum, culture media etc., after previous incubation on indicator cells (Vero). Direct testing incl. DNA extraction and specification of positive results by sequencing.



Report 

Test result is provided in advance via fax when desired. Additional report with a printout of the gel photo is provided. All customer information is treated as strictly confidential.

Formal, contractual confidentiality agreements can be generated upon request.

Reports are maintained in our archives for five years; samples are kept up to six months for retesting at customers' request.



Sample Preparation 

Please find a detailed description of the sample preparation on the sample submission form (PDF, 64 kB).



Shipping Instructions 

The samples can be sent to our laboratory without a telephone announcement for the preparation of the sample material. A complete copy of our sample submission form must be enclosed with all submitted samples.



Special Preparation for Cell Culture Samples 

Cell cultures should be tested at almost complete confluence (95-100%). Elimination of antibiotics is not necessary, however to maximize test sensitivity, cell lines should be pre-cultured in the absence of antibiotics for several days.



Please Note  

Minerva Biolabs does not accept sample material of biological safety level 3 or 4. The offered mycoplasma testing service is not to be used for clinical diagnosis or applications involving humans. This service is intended exclusively for quality control/research purposes only. Samples can only then be accepted when Minerva Biolabs receives the signed sample submission form.




  Bacteria Detection

Ordering:

Test Method Cat.-No.
Direct testing of DNA extracts
41-1002
Testing after cultivation of the sample material
41-2002
Direct testing incl. DNA extraction and specification
41-2002
>>> Ordering Information

Download

Document Size
Submission Form 64 kb
 
           
 
toptop
Update: 11.02.2010   //   Contact   //   International Distributors   //   Terms and Conditions    //   Site Map   //   © 2010 Minerva Biolabs GmbH